Agency-wise Major/critical Ncs at OHT

S.No. Scheme ID Scheme Name OHT Code Non-Compliance Compliance(Current Status)
Description
Major Honey Comb Alignment Cube Test Exposure Deviation Tank Observation Other SBC Issue Demolish Partially Demolish Fully Under Examination Serious Observation Water Body Compliance Major Honey Comb Compliance Alignment Compliance Cube Test Compliance Exposure Compliance Deviation Compliance Tank Compliance Other Compliance SBC Issue Compliance Demolish Partially Compliance Demolish Fully Compliance Under Examination Compliance Serious Observation Compliance Water Body
1 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-09 Yes No No No No No Yes No No No No No No Resolved Resolved Column have been found damaged Share key has not provided Curing arrangement not available PCC thickness have been found 60 mm
2 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-01 No Yes No No No No No No No No No No No Resolved
3 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-89 No Yes No No No No No No No No No No No Resolved
4 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-81 Yes Yes No No No No Yes No No No No No No Resolved Resolved Resolved substandard material found at site
5 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-11 Yes Yes No No No No No No No No No No No Resolved Resolved curing arrangement not found at site shear key not provided rusted steel found at site
6 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-46 No No No No No No Yes No No No No No No Resolved shear key have not provided
7 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-35 Yes Yes No No No No No No No No No No No Resolved Resolved
8 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-91 No No No No No No Yes No No No No No No Resolved proper lapping in raft not provided
9 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-34 Yes No No No No No Yes No No No No No No Resolved Resolved water logging has been observed
10 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-06 Yes No No No No No No No No No No No No Resolved curing arrangement not available at site
11 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-79 No No No No No No Yes No No No No No No Resolved curing arrangement not available at site
12 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-45 Yes No No No No No No No No No No No No Resolved
13 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-112 No No No No No No Yes No No No No No No Resolved proper lapping have not given in the raft
14 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-15 No No No No No No Yes No No No No No No Resolved cover block not provided
15 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-08 Yes No No No No No Yes No No No No No No Resolved Resolved rusted steel have been found at site curing arrangement has not available at site
16 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-10 Yes Yes No No No No Yes No No No No No No Resolved Resolved Resolved rusted steel have been found at site crack has been observed at the 2nd and 3rd list column
17 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-88 No Yes No No No No No No No No No No No Resolved
18 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-29 No No No No No No Yes No No No No No No Resolved water filled at the raft of the OHT
19 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-32 No No No No No No Yes No No No No No No Resolved substandard material found at site Rusted steel have been found
20 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-33 No No No No No No Yes No No No No No No Resolved curing arrangement not available at site
21 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-53 Yes Yes No No No No No No No No No No No Resolved Resolved
22 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-110 No No No No No No Yes No No No No No No Resolved proper lapping have not provided in the raft
23 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-19 No No No No No No Yes No No No No No No Resolved crack has been observed in the first lift column curing arrangement not available at site
24 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-02 Yes No No No No No Yes No No No No No No Resolved Resolved substandard material found at site rusted steel found at site
25 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-57 Yes No No No No No No No No No No No No Resolved proper splicing have not provided
26 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-80 No No No No No No Yes No No No No No No Resolved proper lapping not provided in the raft
27 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-59 Yes No No No No No No No No No No No No Resolved
28 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-92 Yes No No No No No No No No No No No No Resolved
29 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-111 No Yes No No No No No No No No No No No Misalignment has been observed in the column of the OHT.
30 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-93 No No No No No No No No No No No No Yes Resolved Re-SBC Done
31 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-66 No No No No No No Yes No No No No No No The surface of OHT container wall has been observed uneven and bulged.
32 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-18 No No No No No No Yes No No No No No No Walkway slab has been found broken for the last flight staircase. steel bar have found exposed.
33 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-49 Yes No No No No No No No No No No No No Honeycomb has been observed in OHT beam and column.
34 20101490 Prayagraj Dist. Rural Surface Water Supply Scheme(Ganga) GP-22 No No No Yes No No No No No No No No No Beams reinforcement and stirrups are found exposed to atmosphere.